RAID Disk Replacement on IBM Power Platform
Jump to navigation
Jump to search
Removal of a SAS Physical Volume
- # diag
- Select: Task Selection
- Select: Hot Plug Task
- Select: RAID Array Manager
- Select: IBM SAS Disk Array Manager
- Select: Diagnostics and Recovery Options
- Select: SCSI and SCSI Raid Hot Plug Manager
- Select: Replace/Remove a Device Attached to an SCSI Hot Swap Enclosure Device
- Select: Slot # of the pdisk you wish to remove.
- Follow the on-screen instructions to complete removal.
- Exit from diag.
Rebuild the RAID Array
- # diag
- Select: Task Selection
- Select: Hot Plug Task
- Select: RAID Array Manager
- Select: IBM SAS Disk Array Manager
- Select: Reconstruct a SAS Disk Array
- The following screen will show the failed pdisk, press the [Enter] key to select the disk.
- Press: F7 to commit.
- Press: [Enter] at the next screen to begin the reconstruct process.
- This process can take several minutes to several hours.